Flotec FP401215H Manuel d'utilisation et d'entretien Page 4

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 40
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 3
Installation 4
For parts or assistance, call Flotec Customer Service at 1-800-365-6832
Replacing An Old Pump
Hazardous voltage. Disconnect power to pump before working
on pump or motor.
1. Drain and remove the old pump. Check the old pipe for scale, lime,
rust, etc., and replace it if necessary.
2. Install the pump in the system. Make sure that all pipe joints in the
suction pipe are air-tight as well as water tight. If the suction pipe can
suck air, the pump will not be able to pull water from the well.
3. Adjust the pump mounting height so that the plumbing connections do
not put a strain on the pump body. Support the pipe so that the pump
body does not take the weight of piping or fittings.
You have just completed the well plumbing for your new shallow well jet
pump. Please go to Page 6 for discharge pipe and tank connections.
Well Point (Driven Point) Installation (Figure 1)
1. Drive the well, using “drive couplings” and a “drive cap”. “Drive
fittings” are threaded all the way through and allow the pipe ends to
butt against each other so that the driving force of the maul is carried
by the pipe and not by the threads. The ordinary fittings found in
hardware stores are not threaded all the way through the fitting and can
collapse under impact. “Drive fittings” are also smoother than standard
plumbing fittings, making ground penetration easier.
2. Mount the pump as close to the well as possible.
3. Use the fewest possible fittings (especially elbows) when connecting
the pipe from the well point to the pump suction port. The suction pipe
should be at least as large as the suction port on the pump (include
a check valve if your pump is not equipped with one – see Figure
1). Support the pipe so that there are no dips or sags in the pipe, so
it doesn’t strain the pump body, and so that it slopes slightly upward
from the well to the pump (high spots can cause air pockets which can
air lock the pump). Seal the suction pipe joints with PTFE pipe thread
sealant tape or a PTFE-based pipe joint compound. Joints must be air-
and water-tight. If the suction pipe can suck air, the pump cannot pull
water from the well. If one well point does not supply enough water,
consider connecting two or three well points to one suction pipe.
You have just completed the suction piping for your new shallow well jet
pump. Please go to Page 6 for discharge pipe and tank connections.
Cased Well Installation, 2” or Larger Casing (Figure2)
1. Mount the pump as close to the well as possible.
2. Assemble the foot valve, strainer, and well pipe (see Figure 2). Make
sure that the foot valve works freely.
3. Lower the pipe into the well until the strainer is five feet above the
bottom of the well. It should also be at least 10 feet below the well’s
water level while the pump is running in order to prevent the pump
from sucking air. Install a sanitary well seal.
To Household
Water System
Pump Priming
Tee with Plug
or Gauge
10'
Min.
5–10'
Suction Pipe
From Well
Foot
Valve
Priming
Tee and
Plug
Sanitary
Well Seal
Check
Valve
Figure 2: Cased Well Installation
To Household
Water System
Pump Priming
Tee with Plug
or Gauge
Drive
Coupling
Drive
Point
Priming
Tee and
Plug
Drive point
below water
level
Check
Valve
Figure 1: Driven Point Installation
Typical pump
shown herein
not to scale.
Vue de la page 3
1 2 3 4 5 6 7 8 9 ... 39 40

Commentaires sur ces manuels

Pas de commentaire